Spark gap without gamma ray

Share your spectra and discuss their features here
User avatar
Peter-1
Posts: 170
Joined: 07 Oct 2016, 01:45
Location: Germany
Contact:

Re: Spark gap without gamma ray

Post by Peter-1 » 01 Nov 2016, 22:26

thank you MattiaB,

but ! The "Freigrenze" for CS137 in germany is 10 kBq. But the company supplies only CS137 with 15 kBq. Therefore it is not possible for private individuals.
Peter

User avatar
MartinM
Posts: 84
Joined: 21 Apr 2016, 18:12
Contact:

Re: Spark gap without gamma ray

Post by MartinM » 02 Nov 2016, 02:48

Point sources / Gamma Standards—Type D (GF-137-D) are offered from 3,7 kBq.

User avatar
Peter-1
Posts: 170
Joined: 07 Oct 2016, 01:45
Location: Germany
Contact:

Re: Spark gap without gamma ray

Post by Peter-1 » 02 Nov 2016, 08:52

Thanks for the note. I will contact the company once but I dont think that they will supplie to private individuals.
For a simple calibration up to 2600keV I take my ThF4 source as you can see.
ThF4-11-1.jpg
ThF4-11-1.jpg (90.61 KiB) Viewed 10381 times
Peter

User avatar
Peter-1
Posts: 170
Joined: 07 Oct 2016, 01:45
Location: Germany
Contact:

Re: Spark gap without gamma ray

Post by Peter-1 » 02 Nov 2016, 20:04

from Eckert & Ziegler

......Licensing Requirements

It is Company policy to require
written verification of the customer’s
Agreement State or NRC radioactive
materials license for all items. No
orders will be processed without
a copy of the customer’s license
on file at Eckert & Ziegler Isotope
Products (EZIP). ............

Peter

User avatar
MartinM
Posts: 84
Joined: 21 Apr 2016, 18:12
Contact:

Re: Spark gap without gamma ray

Post by MartinM » 02 Nov 2016, 20:21

Yeah, that's the usual experience with lots of such companies. Some even don't respond to queries unless you're from a known company/institution.
I suggest you check Spectrum Techniques - they don't ask anything.

User avatar
Peter-1
Posts: 170
Joined: 07 Oct 2016, 01:45
Location: Germany
Contact:

Re: Spark gap without gamma ray

Post by Peter-1 » 03 Nov 2016, 09:15

Hello,
now I have my test source.
ThF4-Strahler.jpg
ThF4-Strahler.jpg (45.58 KiB) Viewed 10368 times
It is ~ 100mg ThF4 in acryl and epoxy. This was in the past for AR coatings like MgF2 and others. All lines from Thorium are well known from 200 - 2600keV. It works fine.
Peter

luuk
Posts: 313
Joined: 01 May 2015, 21:00
Location: the Netherlands
Contact:

Re: Spark gap without gamma ray

Post by luuk » 04 Nov 2016, 17:42

Hi Peter,
That is an interesting source, were did you got it?
Is it possible to buy?
Luuk

User avatar
Peter-1
Posts: 170
Joined: 07 Oct 2016, 01:45
Location: Germany
Contact:

Re: Spark gap without gamma ray

Post by Peter-1 » 04 Nov 2016, 21:31

Luuk,
Sorry you can not buy this source. DIY :-)
Peter

User avatar
brehwens
Posts: 89
Joined: 27 Apr 2015, 03:49
Contact:

Re: Spark gap without gamma ray

Post by brehwens » 04 Nov 2016, 23:23

Hi

I ordered some sources from Spectrum Techniques. It all got hold up in customs, but as all the paperwork was there it eventually was released and I got my package no questions asked.
Karl Brehwens
Eskilstuna, Sweden.

Setup: 5 cm lead castle, 2mm copper lining. Gamma Spectacular Pro 2002, Sound Blaster Live! 5.1,
Primary detector: Scionix refurbished 2x2" NaI(Tl) well detector, 7.5% @ 662 keV

Post Reply

Who is online