ATOM SWIFT Personal Dosimeter

Atom Swift is a compact keychain radiation dosimeter designed to work with a smartphone or tablet PC. It is capable of detecting and measuring low level Gamma, X-ray, and Beta radiation.


Radioactivity can be measured in order to discover the amount of radiation a material emits or the amount of radiation absorbed by a human.  Some example uses include: personal radiation protection, surveying of land/building/construction materials, vehicle inspection, etc. The Atom Swift is ideal for use at home, work, educational use, or on the go.

 

Atom Swift contains an ultra-sensitive scintillation crystal detector (CsI crystal and silicon photomultiplier) capable of detecting low-energy gamma and X-rays.  


The detector and associated electronics are housed in a robust polycarbonate housing, small enough to hang on a keyring and is powered by one CR2032 lithium battery.

 

Free apps are available in the AppStore (for iOS) or Google Play (for Android).  The app can be used to process information gathered from scintillation detector and show readings on screen. The smartphone or tablet PC app allows you choose between measurement units, set dose rate and accumulated dose alarm level and many other parameters. 


To download the app, refer to the following links:

 

Apple  iOS app: Download


Android option 1: Download

Android option 2: Download 


Standalone Use

Atom Swift can also operate in standalone mode if wireless communication with smartphone or tablet PC is unavailable. There are three user-programmable dose rate and accumulated dose thresholds with different alarm signals.  These thresholds can be programmed by the user for use when in standalone mode.  Information on accumulated dose is stored while Atom Swift is in standalone mode and can be read after establishing wireless communication. A smartphone or tablet PC can be connected to many Atom Swifts at simultaneously.


Work modes:

Atom Swift can operate in two modes: search mode and measurement mode. Toggling of these modes can be changed on the smartphone or tablet PC app. If your device is switched to airplane mode, the Atom Swift continues to operate in standalone mode.


Search mode

In search mode, reaction to radiation dose rate change is fast in expense of measurement accuracy. You can select  between “Fast”, “Balanced” and “Accurate” search modes in application settings according to your needs. In search mode data from the sensor is analysed using sliding window method, time to first reading is less than 10 seconds in “Balanced” search mode under normal radiation background (0,1 uSv/h or 10 uR/h). After the first reading is indicated, it will be updated every two seconds. Search mode is recommended for surveying of land, vehicles, construction materials etc.


Measurement mode

In measurement mode, Atom Swift gathers information from the scintillation detector continuously until the manual reset button is pressed and indicates current statistical error which decreases with measurement time. You can start new measurement any time by pressing “Reset” button on the measurement screen. Measurement mode is suitable for detecting very low activity sources by comparison of two dose rates: background dose rate and dose rate close to possible source of radiation. Try not to move the Atom Swift during measurement to get most accurate readings. Please note that statistical accuracy increases by square root law: you need to make four times (4x) longer measurement to get twice (2x) accurate result.


Change settings or turning unit on and off

The Atom Swift has no physical buttons, instead it contains an accelerometer which allows the user to change settings without the use of a smartphone or tablet PC.  Many settings can be controlled by flipping the Atom-Swift 360˚ one or more times along either planar axis.


Technical specifications:

 

Types of radiation detected

Gamma, X-ray, Beta

Dose rate measurement range

0,01 uSv/h – 100 uSv/h (1 uR/h – 10 mR/h)

Maximum count rate

10 000 CPS (600 000 CPM) min.

Energies of gamma- and X-rays detected

40 kEv – 10 MEv min.

Detector sensitivity

1700 pulses per uR (47 CPS per uSv/h) typ.

Detector size and material

5*5*30 mm CsI

Sensitivity anisotropy, Cs137

30% max.

Energies of beta-radiation detected

500 kEv and higher

Accumulated dose measurement range

1 nSv – 1 Sv (0,1 uR – 100 R)

Dose rate measurement accuracy with background gamma spectrum

15% max

CR2032 battery lifetime under normal radiation background and no sounds emitted

3 months min. or 6 months min. with Bluetooth switched OFF

Line-of-sight wireless communication distance with iPhone, HTC One or Nexus 5 smartphones

15 m min.

Size

53*50*12 mm ( 2.15” * 2” * 0,47” )

Weight

20 g max (0.7 Oz max)

Environment temperature

-40...+40C

Write a review

Note: HTML is not translated!
    Bad           Good

ATOM-SWIFT Personal Dosimeter

  • Product Code: ATOM-SWIFT
  • Availability: 10
  • USD $299.00


Tags: geiger counter, dosimeter, radiation detector, scintillation detector, sipm, gammaspectacular

Refund & Return Policy

We want you to be 100% happy with your Gammaspectacular product, and offer free after sales support to get you up and running.

If you for any reason you require a refund or replacement, please contact us within 30 days of purchase to arrange the return.
Return shipping cost and risk is the sole responsibility of the buyer.

Return shipping address: Bee Research, Po Box 6259, Alexandria, NSW 2020, Australia